1.
Front Public Health ; 10: 1052610, 2022.
Artigo em Inglês | MEDLINE | ID: covidwho-2242682

RESUMO

During the COVID-19 pandemic, many buildings in northeast China have had clusters of infected cases in the vertical layout. There is speculation that vertical aerosol transmission occurs. The houses in northeast China are airtight, and range hoods may be used for a long period of time when cooking. The pathway and factors influencing vertical aerosol transmission are worth studying. To elucidate a viral aerosol transmission pathway, we selected a multistory apartment and a high-rise building in Changchun city, Jilin province, China, to conduct an in-depth investigation and on-site simulation experiments. According to epidemiological investigation information on infected cases, building structures, drainage, ventilation, etc., we used fluorescent microspheres to simulate the behaviors of infected people, such as breathing and flushing the toilet after defecation, to discharge simulated viruses and track and monitor them. The field simulation experiment confirmed the transmission of fluorescent microsphere aerosols to other rooms in two types of buildings using a vertical aerosol transmission pathway of toilet flush-sewage pipe-floor drain without a water seal. Our study showed that, in the absence of a U-shaped trap or floor drain water seal whether in a multistory apartment or high-rise residential building, there is a transmission pathway of "excretion of virus through feces-toilet flushing-sewage pipe-floor drain without water seal," which will cause the vertical transmission of viral aerosol across floors during the COVID-19 pandemic. Moreover, the negative pressure generated by turning on the range hood when closing doors and windows increase aerosol transmission. Based on this negative pressure, prevention and control measures for residential buildings in northeast China during the COVID-19 pandemic were proposed.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Pandemias , Esgotos , Aerossóis e Gotículas Respiratórios , China/epidemiologia
2.
China CDC Wkly ; 5(1): 1-4, 2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: covidwho-2232799

RESUMO

What is already known about this topic?: There is a toilet flush-soil stack-floor drain pathway of aerosol transmission in multistory and high-rise buildings, but the influencing factors are not completely clear. What is added by this report?: The poor airtightness of the connecting parts of the floor drain, as well as pressure fluctuations in the sewage pipe during toilet flushing caused by blockage of the soil stack vent, may lead to the cross-floor transmission of viral aerosols through the soil stack and floor drains. What are the implications for public health practice?: In multistory and high-rise buildings, the bathroom floor drains should be kept sealed, and floor drain connecting parts should be airtight. Furthermore, the soil stack vent should not be blocked. In this way, the cross-floor transmission of viral aerosols can be effectively reduced.

3.
Int J Environ Res Public Health ; 20(1)2023 01 03.
Artigo em Inglês | MEDLINE | ID: covidwho-2166539

RESUMO

SARS-CoV-2 genetic sequence results collected from native COVID-19 cases who waited or saw relatives off at Xi'an Xianyang International Airport were highly consistent with the imported cases. In order to explore the routes of transmission and influencing factors that may cause the transmission of SARS-CoV-2 at the airport, a field simulation experiment of aerosol diffusion was adopted based on epidemiological survey data and a detailed field investigation of airport structure and ventilation. The results showed that the inbound passengers waited for approximately 3 h in the rest area on the first level of the international arrival area (Zone E). During the period, masks were removed for eating and drinking, resulting in the viral aerosols rising from the first level to the second level with hot air. After deplaning, the inbound passengers handled the relevant procedures and passed through the corridor on the second floor. The local side wall of the corridor adopted fan coil air conditioning, combined with fresh air supply and personnel walking, resulting in airflow flowing to Zone E. After merging with diffused air containing virus aerosol from the first floor, it continued to spread upward to the connected third-layer area. There was a local suspended ceiling on the top of the third floor, but it was approximately 4 m high and connected to the corridor from Terminal 2 to Terminal 3. When the virus aerosol diffused above the Terminal 2-Terminal 3 corridor, where the temperature was low and the air diffused downward, it could cause an infection risk for people passing through the corridor. In addition, the investigation found that the exhaust pipes of the nucleic acid sampling rooms at the international arrival corridor were directly discharged outdoors without treatment. Only one exhaust pipe and poor ventilation in the bathroom in Zone E had a risk of viral aerosol diffusion. Therefore, the international arrival area should be set up alone or separated from the other areas by hard isolation to avoid the existence of communication between different areas that could cause viral aerosols to diffuse with airflow. The toilet ventilation should be increased to avoid the accumulation of viral aerosols at high concentrations. The exhaust pipes of the toilet and the nucleic acid sampling rooms should be equipped with disinfection and efficient filtration devices, and high-altitude emission should be adopted to reduce the risk of virus aerosol diffusion.


Assuntos
COVID-19 , Ácidos Nucleicos , Humanos , SARS-CoV-2 , COVID-19/epidemiologia , Aeroportos , Aerossóis e Gotículas Respiratórios
4.
China CDC Wkly ; 4(26): 565-569, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: covidwho-1912763

RESUMO

What is already known about this topic?: Environmental factors such as temperature and humidity play important roles in the transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) via droplets/aerosols. What is added by this report?: Higher relative humidity (61%-80%), longer spreading time (120 min), and greater dispersal distance (1 m) significantly reduced SARS-CoV-2 pseudovirus loads. There was an interaction effect between relative humidity and spreading time. What are the implications for public health practice?: The findings contribute to our understanding of the impact of environmental factors on the transmission of SARS-CoV-2 via airborne droplets/aerosols.

5.
China CDC Wkly ; 4(23): 489-493, 2022 Jun 10.
Artigo em Inglês | MEDLINE | ID: covidwho-1893718

RESUMO

What is already known about this topic?: Aerosol transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) via sanitary pipelines in high-rise buildings is possible, however, there is a lack of experimental evidence. What is added by this report?: The field simulation experiment confirmed the existence of a vertical aerosol transmission pathway from toilet flush-soil stack-floor drains without water seal. This report provided experimental evidence for vertical aerosol transmission of clustered outbreaks on 18 floors of a 33-story residential building. What are the implications for public health practice?: The water seal on floor drains is a necessary barrier to prevent the risk of vertical aerosol transmission of infectious disease pathogens in buildings. It is necessary not only to have a U-shaped trap in the drainage pipe, but also to be filled with water regularly.

7.
China CDC Wkly ; 4(10): 191-194, 2022 Mar 11.
Artigo em Inglês | MEDLINE | ID: covidwho-1699557

RESUMO

In light of the severity of coronavirus disease (COVID-19) around the world, it is an arduous task for China to prevent COVID-19 from being imported from abroad and proliferating domestically. The community is the first and most effective line of defense and can effectively cut off the channels of spread of the epidemic. In order to reduce risks of COVID-19 transmission in the community, it is necessary to sort out the loopholes in risk and management, as well as investigate previous epidemic transmission events in the community.

8.
Int J Environ Res Public Health ; 19(3)2022 01 29.
Artigo em Inglês | MEDLINE | ID: covidwho-1667139

RESUMO

A cross-layer non-vertical transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) occurred in a quarantine hotel in Guangzhou, Guangdong Province, China in June 2021. To explore the cross-layer transmission path and influencing factors of viral aerosol, we set up different scenarios to carry out simulation experiments. The results showed that the air in the polluted room can enter the corridor by opening the door to take food and move out the garbage, then mix with the fresh air taken from the outside as part of the air supply of the central air conditioning system and re-enter into different rooms on the same floor leading to the same-layer transmission. In addition, flushing the toilet after defecation and urination will produce viral aerosol that pollutes rooms on different floors through the exhaust system and the vertical drainage pipe in the bathroom, resulting in cross-layer vertical transmission, also aggravating the transmission in different rooms on the same floor after mixing with the air of the room and entering the corridor to become part of the air supply, and meanwhile, continuing to increase the cross-layer transmission through the vertical drainage pipe. Therefore, the air conditioning and ventilation system of the quarantine hotel should be operated in full fresh air mode and close the return air; the exhaust volume of the bathroom should be greater than the fresh air volume. The exhaust pipe of the bathroom should be independently set and cannot be interconnected or connected in series. The riser of the sewage and drainage pipeline of the bathroom should maintain vertical to exhaust independently and cannot be arbitrarily changed to horizontal pipe assembly.


Assuntos
COVID-19 , SARS-CoV-2 , Aerossóis , Ar Condicionado , Humanos , Quarentena
9.
Environ Technol Innov ; 25: 102165, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: covidwho-1568695

RESUMO

Face masks are critical in preventing the spread of respiratory infections including coronavirus disease 2019 (COVID-19). Different types of masks have distinct filtration efficiencies (FEs) with differential costs and supplies. Here we reported the impact of breathing volume and wearing time on the inward and outward FEs of four different mask types (N95, surgical, single-use, and cloth masks) against various sizes of aerosols. Specifically, 1) Mask type was an important factor affecting the FEs. The FEs of N95 and surgical mask were better than those of single-use mask and cloth mask; 2) As particle size decreased, the FEs tended to reduce. The trend was significantly observed in FEs of aerosols with particle size < 1 µ m ; 3) After wearing N95 and surgical masks for 0, 2, 4, and 8 h, their FEs (%) maintained from 95.75 ± 0.09 to 100 ± 0 range. While a significant decrease in FEs were noticed for single-use masks worn for 8 h and cloth masks worn >2 h under deep breathing (30 L/min); 4) Both inward and outward FEs of N95 and surgical masks were similar, while the outward FEs of single-use and cloth masks were higher than their inward FEs; 5) The FEs under deep breathing was significantly lower than normal breathing with aerosol particle size <1 µ m. In conclusion, our results revealed that masks have a critical role in preventing the spread of aerosol particles by filtering inhalation, and FEs significantly decreased with the increasing of respiratory volume and wearing time. Deep breathing may cause increasing humidity and hence decrease FEs by increasing the airflow pressure. With the increase of wearing time, the adsorption capacity of the filter material tends to be saturated, which may reduce FEs. Findings may be used to provide information for policies regarding the proper use of masks for general public in current and future pandemics.

10.
China CDC Wkly ; 3(41): 859-862, 2021 Oct 08.
Artigo em Inglês | MEDLINE | ID: covidwho-1456702
11.
China CDC Wkly ; 3(34): 711-715, 2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: covidwho-1366005

RESUMO

WHAT IS ALREADY KNOWN ON THIS TOPIC?: Aerosol transmission was one route for the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and usually occurred in confined spaces. WHAT IS ADDED BY THIS REPORT?: Aerosol transmission was found to exist between handshake buildings, i.e., buildings with extremely close proximity that formed relatively enclosed spaces. Transmission was mainly affected by the airflow layout caused by switching air conditioners on and off as well as opening and closing doors and windows. WHAT ARE THE IMPLICATIONS FOR PUBLIC HEALTH PRACTICE?: Centralized isolation and home isolation in handshake buildings creates a risk of SARS-CoV-2 aerosol transmission under certain conditions. Attention should be paid to the influence of air distribution layout on aerosol diffusion in isolation wards, and disinfection of isolation venues should be strengthened.

12.
Sci Total Environ ; 778: 146040, 2021 Jul 15.
Artigo em Inglês | MEDLINE | ID: covidwho-1117650

RESUMO

From June 11, 2020, a surge in new cases of coronavirus disease 2019 (COVID-19) in the largest wholesale market of Beijing, the Xinfadi Market, leading to a second wave of COVID-19 in Beijing, China. Understanding the transmission modes of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and the personal behaviors and environmental factors contributing to viral transmission is of utmost important to curb COVID-19 rise. However, currently these are largely unknown in food markets. To this end, we completed field investigations and on-site simulations in areas with relatively high infection rates of COVID-19 at Xinfadi Market. We found that if goods were tainted or personnel in market was infected, normal transaction behaviors between sellers and customers, daily physiological activities, and marketing activities could lead to viral contamination and spread to the surroundings via fomite, droplet or aerosol routes. Environmental factors such as low temperature and high humidity, poor ventilation, and insufficient hygiene facilities and disinfection practices may contribute to viral transmission in Xinfadi Market. In addition, precautionary control strategies were also proposed to effectively reduce the clustering cases of COVID-19 in large-scale wholesale markets.


Assuntos
COVID-19 , SARS-CoV-2 , Pequim/epidemiologia , China/epidemiologia , Humanos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA